• DocumentCode
    785823
  • Title

    The Multiplex Control System for the Cornell 10-GeV Synchrotron

  • Author

    Littauer, Raphael ; Pfeffer, Howard

  • Author_Institution
    Laboratory of Nuclear Studies, Cornell University Ithaca, New York
  • Volume
    14
  • Issue
    3
  • fYear
    1967
  • fDate
    6/1/1967 12:00:00 AM
  • Firstpage
    1050
  • Lastpage
    1052
  • Abstract
    The outlines of a time-sharing multiplex control system for the Cornell 10-GeV electron synchrotron were presented at the First National Particle Accelerator Conference, March 19651. The synchrotron is now nearing completion; injection studies involving more than half the guide-field ring were carried out in 1966. At that time, the multiplex control system was working for most of the needed parameters: we report below on the results of this operating experience. We also present an outline of the steps which are being taken to use a computer for supervision and control of many of the accelerator components.
  • Keywords
    Attenuation; Cables; Clocks; Conductors; Control systems; Linear particle accelerator; Magnets; Synchrotrons; Time sharing computer systems; Wideband;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1967.4324703
  • Filename
    4324703