DocumentCode :
785944
Title :
High current beam scanner
Author :
Wegner, H.E. ; Feigenbaum, I.L.
Author_Institution :
Brookhaven National Laboratory Upton, New York
Volume :
14
Issue :
3
fYear :
1967
fDate :
6/1/1967 12:00:00 AM
Firstpage :
1099
Lastpage :
1105
Abstract :
It has been shown that a commerciallyavailable scanner can be modified by the addition of an axial marker generator and water-cooled tubes in place of wires so that it can routinely scan high-current accelerator beams up to beam power densities of at least 35 kW/cm2. The versatility of the scanner has been demonstrated by its use with several different accelerators. In all cases, the installation of the scanner involved only simple adaptation to an existing beam pipe and the device was usually in place and functioning properly in less than an hour´s time.
Keywords :
Ion accelerators; Ion beams; Magnetic resonance; Particle beams;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1967.4324715
Filename :
4324715
Link To Document :
بازگشت