DocumentCode
785987
Title
Measurement of Charge Emission from Targets as a Means of Burst Intensity and Beam Intensity Monitoring
Author
Budal, K.
Author_Institution
European Organization for Nuclear Research Geneva, Switzerland
Volume
14
Issue
3
fYear
1967
fDate
6/1/1967 12:00:00 AM
Firstpage
1132
Lastpage
1137
Abstract
Internal and external operational targets for the CERN Proton Synchrotron have been electrically insulated and the charge emission from the targets measured as a means of burst intensity monitoring. Charge emission from plates placed in ejected beams have been used for beam intensity monitoring. The measurements presented here concern linearity, saturation and reproduceability tests and investigations of the various parameters influencing the signal level. The main contribution to the signal comes from 6-rays which escape from the target. Theoretical results are presented and compared with experimental results.
Keywords
Charge measurement; Current measurement; Dielectrics and electrical insulation; Linearity; Monitoring; Particle beam measurements; Protons; Relays; Telescopes; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1967.4324720
Filename
4324720
Link To Document