Abstract
Precision coaxial air-dielectric transmission lines (air lines) are used as primary impedance standards at RF. An important aspect in the characterisation of these lines is the determination of the inherent loss. Attenuation measurements made at the National Physical Laboratory (NPL), UK are presented showing excellent agreement with values predicted by transmission line theory.
Keywords
attenuation measurement; coaxial cables; electric impedance measurement; measurement standards; transmission line theory; transmission lines; NPL; National Physical Laboratory; air lines; attenuation; coaxial air-dielectric transmission lines; coaxial lines; inherent loss; primary impedance standards; transmission line theory;