Abstract :
A compensated ionization chamber, the WX-5362, has been developed for use in the NERVA program as a neutron flux detector for reactor control. The chamber has been designed to withstand the extremes of radiation, temperature, shock and vibration associated with the NERVA reactor.
Keywords :
Current density; Electric shock; Gamma ray detection; Gamma ray detectors; Inductors; Ionization chambers; Neutrons; Temperature; Testing; Vibrations;