DocumentCode :
787019
Title :
A Gamma Compensated Neutron Ionization Chamber Detector for the Nerva Reactor
Author :
Todt, William H.
Author_Institution :
Westinghouse Electric Corporation Electronic Tube Division Elmira, New York
Volume :
15
Issue :
1
fYear :
1968
Firstpage :
9
Lastpage :
14
Abstract :
A compensated ionization chamber, the WX-5362, has been developed for use in the NERVA program as a neutron flux detector for reactor control. The chamber has been designed to withstand the extremes of radiation, temperature, shock and vibration associated with the NERVA reactor.
Keywords :
Current density; Electric shock; Gamma ray detection; Gamma ray detectors; Inductors; Ionization chambers; Neutrons; Temperature; Testing; Vibrations;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1968.4324823
Filename :
4324823
Link To Document :
بازگشت