• DocumentCode
    787037
  • Title

    Maximum likelihood reconstruction for pinhole SPECT with a displaced center-of-rotation

  • Author

    Jianying Li ; Jaszczak, R.J. ; Coleman, R.E.

  • Author_Institution
    Dept. of Radiol., Duke Univ. Med. Center, Durham, NC
  • Volume
    14
  • Issue
    2
  • fYear
    1995
  • fDate
    6/1/1995 12:00:00 AM
  • Firstpage
    407
  • Lastpage
    409
  • Abstract
    The authors describe the implementation of a maximum likelihood (ML) algorithm using expectation maximization (EM) for pinhole SPECT with a displaced center-of-rotation. A ray-tracing technique is used in implementing the ML-EM algorithm. The proposed ML-EM algorithm is able to correct the center of rotation displacement which can be characterized by two orthogonal components. The algorithm is tested using experimentally acquired data, and the results demonstrate that the pinhole ML-EM algorithm is able to correct artifacts associated with the center-of-rotation displacement
  • Keywords
    image reconstruction; medical image processing; single photon emission computed tomography; artifacts correction; center-of-rotation displacement; displaced center-of-rotation; experimentally acquired data; maximum likelihood reconstruction; medical diagnostic imaging; nuclear medicine; orthogonal components; pinhole SPECT; ray-tracing technique; Geometry; Image reconstruction; Image resolution; Iterative methods; Optical collimators; Ray tracing; Reconstruction algorithms; Single photon emission computed tomography; Testing; Time measurement;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/42.387721
  • Filename
    387721