• DocumentCode
    787052
  • Title

    Summary of an Analysis of the Eddy-Current Flowmeter

  • Author

    Wiegand, David E.

  • Author_Institution
    Argonne National Laboratory Argonne, Illinois
  • Volume
    15
  • Issue
    1
  • fYear
    1968
  • Firstpage
    28
  • Lastpage
    36
  • Abstract
    The eddy-current flowmeter seems well adapted to measurements in high-temperature liquid-metal systems, where deterioration of the properties of permanent magnets and other ferromagnetic parts or bearing problems may seriously degrade the performance of other types. It is shown analytically that velocity-profile errors and temperature errors can be minimized by selecting a suitable operating frequency.
  • Keywords
    Area measurement; Coils; Frequency measurement; Magnetic analysis; Magnetic field measurement; Magnetic fields; Magnetic liquids; Solenoids; Temperature measurement; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1968.4324826
  • Filename