DocumentCode :
788241
Title :
The Possibilities of Using CdTe as a Gamma Spectrometer
Author :
Akutagawa, W. ; Zanio, K.
Author_Institution :
Hughes Research Laboratories Malibu, California
Volume :
15
Issue :
3
fYear :
1968
fDate :
6/1/1968 12:00:00 AM
Firstpage :
266
Lastpage :
274
Abstract :
Photopeaks have been resolved from monoenergetic gammas within the 122 to 840 keV range using 40 mm3 surface barrier CdTe detectors operated at room temperature and under less than full collection conditions. Presently available CdTe exhibits heavy charge trapping and the gamma spectra reflect the effect of trapping and detrapping under changes of temperature, bias, and clipping time.
Keywords :
Conductivity; Crystalline materials; Crystals; Energy resolution; Gamma ray detection; Gamma ray detectors; Laboratories; Photonic band gap; Spectroscopy; Temperature;