DocumentCode
788292
Title
Charge Collection in Coaxial Ge(Li) Detectors
Author
Sakai, Eiji
Author_Institution
Physics Division, Chalk River Nuclear Laboratories, Atomic Energy of Canada Limited, Chalk River, Ontario, Canada
Volume
15
Issue
3
fYear
1968
fDate
6/1/1968 12:00:00 AM
Firstpage
310
Lastpage
320
Abstract
Cylindrical double-open-end coaxial Ge(Li) detectors have been studied at 77°K using a small-area (circular) collimated beam of 137Cs ¿-rays. The beam was aimed parallel to the detector axis and moved across a diameter. On different detectors, different trapping effects were observed; one detector gave better resolution and a greater pulse height when irradiated near the p-type core, another gave best performance when irradiated near the outer n+-layer. The observed pulse shapes for different positions of irradiation showed general agreement with calculated pulse shapes based on an assumed r-1 variation of electric field across the i-region.
Keywords
Coaxial components; Collimators; Detectors; Face detection; Pulse amplifiers; Pulse measurements; Pulse shaping methods; Shape; Space vector pulse width modulation; US Department of Energy;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1968.4324952
Filename
4324952
Link To Document