DocumentCode
788701
Title
Non-Magnetic Digitized Readouts for Spark Chambers
Author
Droege, Thomas F. ; Perez-Mendez, Victor ; Stoker, Gerald
Author_Institution
Princeton-Pennsylvania Accelerator Princeton University, Princeton, New Jersey
Volume
15
Issue
3
fYear
1968
fDate
6/1/1968 12:00:00 AM
Firstpage
594
Lastpage
600
Abstract
Magnetostrictive spark chambers are operated with difficulty in magnetic fields. By inducing secondary sparks to a pickup wire, signals can be generated which are similar to those from a magnetostrictive chamber but which are unaffected by magnetic fields. Piezoelectric pickup transducers complete a field insensitive digital spark chamber system.
Keywords
Coils; Low voltage; Magnetic field measurement; Magnetic fields; Magnetic shielding; Magnetostriction; Signal generators; Sparks; Testing; Wire;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1968.4324989
Filename
4324989
Link To Document