DocumentCode :
789684
Title :
Poly- \\alpha Olefin Synthetic Oil: A New Paradigm in Repetitive High-Pressure Oil Switches
Author :
Norgard, Peter ; Curry, Randy D. ; Sears, R.
Author_Institution :
Dept. of Electr. & Comput. Eng., Missouri Univ.
Volume :
34
Issue :
5
fYear :
2006
Firstpage :
1662
Lastpage :
1669
Abstract :
A high-pressure oil switch for high-energy systems has been developed and tested to repetition rates up to 100 pps in burst mode and test voltages to -300 kV. The switch utilizes high-pressure flowing synthetic oil and advanced mechanical designs to achieve high-performance operation at pressures to 17.24 MPa (2500 psi). Experimental data is presented for both single-shot performance as well as continuous repetition rate performance to 20 pps. Electrode lifetime is evaluated for stainless steel and Elkonite to demonstrate electrode lifetime. Evidence is presented in support of the dependence of switching performance on the geometry of the switch
Keywords :
electrodes; insulating oils; remaining life assessment; switchgear insulation; switchgear testing; -300 kV; 17.24 MPa; electrode lifetime evaluation; elkonite; high-pressure flowing synthetic oil; poly-alpha olefin synthetic oil; repetitive high-pressure oil switches; stainless steel; Absorption; Avalanche breakdown; Dielectric breakdown; Dielectric liquids; Electrodes; Petroleum; Steel; Switches; System testing; Voltage; High pressure; high-voltage switch; liquid dielectric; oil switch; rep-rate switch;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/TPS.2006.883340
Filename :
1710024
Link To Document :
بازگشت