• DocumentCode
    789827
  • Title

    Determination of total transformer losses resulting from semirotating flux excitation

  • Author

    Adly, Amr A.

  • Author_Institution
    Dept. of Electr. Power & Machines, Cairo Univ., Giza, Egypt
  • Volume
    31
  • Issue
    6
  • fYear
    1995
  • fDate
    11/1/1995 12:00:00 AM
  • Firstpage
    4253
  • Lastpage
    4255
  • Abstract
    Theoretical and experimental studies have shown that hysteresis losses in a magnetic material subject to an applied rotating field decreases considerably as the field amplitude drives the magnetization into saturation. Recently, low core loss transformers operating with semirotating flux excitation have been proposed. The purpose of this paper is to present an analytical investigation of the overall iron and copper losses of such transformers. In this analysis, core magnetic properties are accurately represented and simulated using vector Preisach models. A sample design for a 110 V, 165 VA single-phase transformer with semirotating flux excitation is given and quantitative analytical results are used as a guide to determine its optimum operating conditions
  • Keywords
    eddy current losses; magnetic flux; magnetic hysteresis; magnetic leakage; magnetisation; power transformers; applied rotating field; core magnetic properties; field amplitude; hysteresis losses; low core loss transformers; semirotating flux excitation; total transformer losses; vector Preisach models; Circuit faults; Copper; Core loss; Iron; Magnetic analysis; Magnetic hysteresis; Magnetic losses; Magnetic materials; Magnetization; Transformer cores;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.489943
  • Filename
    489943