• DocumentCode
    789907
  • Title

    Study of a Compact HPM System With a Reflex Triode and a Marx Generator

  • Author

    Appelgren, Patrik ; Akyuz, Mose ; Elfsberg, Mattias ; Hurtig, Tomas ; Larsson, Anders ; Nyholm, Sten E. ; Möller, Cecilia

  • Author_Institution
    Grindsjon Res. Centre, Swedish Defence Res. Agency, Tumba
  • Volume
    34
  • Issue
    5
  • fYear
    2006
  • Firstpage
    1796
  • Lastpage
    1805
  • Abstract
    To study the performance of compact systems for microwave generation, a series of experiments have been performed with a microwave source powered directly by a Marx generator. The system consists of a 20-stage 400-kV/400-J Marx generator, a powerful 40-kV charger, a reflex triode, and a vircator-type microwave source. Different parametric studies were performed such as variation of the anode-cathode distances and the emitting area of the cathode. The results have been analyzed and compared to an equivalent electric circuit model of the system. The experiments, generating microwave frequencies between 3 and 5 GHz, can be fairly accurately reproduced by the model both in terms of discharge currents and microwave frequencies
  • Keywords
    discharges (electric); equivalent circuits; microwave generation; pulsed power supplies; triodes; vircators; 3 to 5 GHz; 40 kV; 400 J; 400 kV; Marx generator; compact HPM system; discharge currents; microwave generation; reflex triode; vircator-type microwave source; Circuits; High power microwave generation; Impedance; Microwave frequencies; Microwave generation; Power generation; Power system modeling; Pulse generation; Pulse power systems; Voltage; Electron beams; Marx generators; microwave generation; pulsed power systems;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.2006.881889
  • Filename
    1710043