DocumentCode :
789907
Title :
Study of a Compact HPM System With a Reflex Triode and a Marx Generator
Author :
Appelgren, Patrik ; Akyuz, Mose ; Elfsberg, Mattias ; Hurtig, Tomas ; Larsson, Anders ; Nyholm, Sten E. ; Möller, Cecilia
Author_Institution :
Grindsjon Res. Centre, Swedish Defence Res. Agency, Tumba
Volume :
34
Issue :
5
fYear :
2006
Firstpage :
1796
Lastpage :
1805
Abstract :
To study the performance of compact systems for microwave generation, a series of experiments have been performed with a microwave source powered directly by a Marx generator. The system consists of a 20-stage 400-kV/400-J Marx generator, a powerful 40-kV charger, a reflex triode, and a vircator-type microwave source. Different parametric studies were performed such as variation of the anode-cathode distances and the emitting area of the cathode. The results have been analyzed and compared to an equivalent electric circuit model of the system. The experiments, generating microwave frequencies between 3 and 5 GHz, can be fairly accurately reproduced by the model both in terms of discharge currents and microwave frequencies
Keywords :
discharges (electric); equivalent circuits; microwave generation; pulsed power supplies; triodes; vircators; 3 to 5 GHz; 40 kV; 400 J; 400 kV; Marx generator; compact HPM system; discharge currents; microwave generation; reflex triode; vircator-type microwave source; Circuits; High power microwave generation; Impedance; Microwave frequencies; Microwave generation; Power generation; Power system modeling; Pulse generation; Pulse power systems; Voltage; Electron beams; Marx generators; microwave generation; pulsed power systems;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/TPS.2006.881889
Filename :
1710043
Link To Document :
بازگشت