Title :
A Slow Extracted Beam for the Cornell 2 GeV Synchrotron
Author :
Browman, A. ; Hand, Louis N. ; Rouse, G. ; Tso, T.
Author_Institution :
Cornell University, Ithaca, New York
fDate :
6/1/1969 12:00:00 AM
Abstract :
The electron beam at the Cornell 2 GeV synchrotron has been extracted using independently controlled quadrupole and octupole magnets. The septum used has sufficient bend to avoid the synchrotron fringe field. The extracted beam has a divergence of less than 0.5 mrad., a size of 2 mm x 2 mm, a momentum spread less than 0.25% and an intensity greater than 109 electron/pulse (30 pulses/second. The beam is stable, easy to obtain and parasitic operation is possible.
Keywords :
Apertures; Assembly; Copper; Electron beams; Frequency; Magnets; Resonance; Steel; Structural beams; Synchrotrons;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1969.4325228