• DocumentCode
    792374
  • Title

    Gamma-Guided Stereotactic Breast Biopsy System

  • Author

    Welch, Benjamin ; Brem, Rachel ; Kross, Brian ; Popov, Vladimir ; Wojcik, Randy ; Majewski, Stan

  • Author_Institution
    Thomas Jefferson Nat. Accelerator Facility, Newport News, VA
  • Volume
    53
  • Issue
    5
  • fYear
    2006
  • Firstpage
    2690
  • Lastpage
    2697
  • Abstract
    A gamma-ray imaging system has been developed for acquiring stereo images of the distribution of radiopharmaceuticals in breast tissue. The system consists of a small field-of-view gamma-ray camera mounted to a stereotactic biopsy table. The camera is mounted on a rotational arm such that it can be used to image the breast from two 15deg stereo views. These stereo images can be used to determine the three dimensional spatial location of a region of focal uptake. Once the location of this region is determined, this information can be used as a guide for stereotactic core needle biopsy. The accuracy that the spatial location of a source can be determined was investigated by moving a point source within the field of view. A center-of gravity calculation was used to localize the centroid of the image of the source and this was used to determine the spatial location. Measurements indicate that the source can be localized to within 1 mm. A comparison of the operation of the gamma imaging system and an x-ray imaging system has been done using a dual modality phantom. These measurements indicated that the spatial location of an isolated source can be determined by the gamma imaging system to within approximately the same performance criteria as required for the X-ray system (1 mm). Collimators were tested to determine the spatial resolution in the transverse dimension and the impact of this transverse resolution on the axial resolution was investigated. The performance of this gamma-guided stereotactic biopsy system will be presented
  • Keywords
    biological organs; collimators; gamma-ray apparatus; gamma-ray detection; image resolution; mammography; phantoms; pharmaceuticals; radioisotope imaging; axial resolution; breast tissue; center-of gravity calculation; collimators; dual modality phantom; gamma-guided stereotactic biopsy system; gamma-ray camera; gamma-ray imaging system; radiopharmaceutical distribution; spatial resolution; transverse resolution; Breast biopsy; Breast tissue; Cameras; Gravity; Imaging phantoms; Needles; Nuclear imaging; Optical imaging; Spatial resolution; X-ray imaging; Biopsy; breast cancer; gamma camera; stereotactic;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2006.876002
  • Filename
    1710257