• DocumentCode
    792546
  • Title

    Rotor Protection of Large Motors by Use of Direct Temperature Monitoring

  • Author

    Smith, F.D. ; Hanson, K.L.

  • Author_Institution
    Electric Machinery Manufacturing Company, Minneapolis, Minn. 55413.
  • Issue
    4
  • fYear
    1975
  • fDate
    7/1/1975 12:00:00 AM
  • Firstpage
    340
  • Lastpage
    343
  • Abstract
    The cage winding of an induction or a synchronous motor can be protected against excessive heating when the temperature of the cage is made available in the motor control room. An explanation of a practical system that provides direct cage temperature readout plus adjustable setting alarm contacts is presented.
  • Keywords
    Acceleration; Induction motors; Protection; Protective relaying; Relays; Rotors; Stators; Synchronous motors; Temperature measurement; Temperature sensors;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.1975.349305