Title :
Power Semiconductor Equipment Cooling Methods and Application Criteria
Author :
McLaughlin, Michael H. ; Vonzastrow, E.
Author_Institution :
Research and Development Center, General Electric Company, Schenectady, N. Y. 12301.
Abstract :
A variety of factors including cost effectiveness, output rating, and reliability influence the choice of cooling method for semiconductor power conversion equipment. For this study, a number of representative cooling systems (air, water, immersion) were evaluated for a 700 V ac to adjustable voltage dc conversion equipment. A transient thermal model of an external pressure-mounted double-side cooled thyristor (such as a Press Pak, Hockey Puk, Disk Pac, etc.) was used to demonstrate the transient time frame over which changes in the cooling system affect the system rating. The systems evaluated provided a range of system performance and demonstrated the need for careful definition of application requirements.
Keywords :
Cooling; Costs; Power conversion; Power system reliability; Semiconductor device packaging; Semiconductor device reliability; Temperature; Thermal resistance; Thyristors; Water pollution;
Journal_Title :
Industry Applications, IEEE Transactions on
DOI :
10.1109/TIA.1975.349340