DocumentCode :
793591
Title :
The Cascade Connection of Switching Regulators
Author :
Matsuo, Hirofumi ; Harada, Koosuke
Author_Institution :
Department of Electronics, Kyushu University, Fukuoka, Japan.
Issue :
2
fYear :
1976
fDate :
3/1/1976 12:00:00 AM
Firstpage :
192
Lastpage :
198
Abstract :
A method for the cascade connection of switching regulators is introduced which is useful for low-voltage power supplies. It is common to use a reactor with a secondary winding in order to obtain a sufficiently small step-down ratio (Eout/Ein). In this method, how-ever, a switching surge occurs because of the leakage inductance of the two-winding reactor. On the other hand, by the method presented here, we will be able to have a sufficiently small step-down ratio and a sufficiently large regulation range with no occurrence of the switching surge. Furthermore, a new method is proposed for isolating the supply and the load circuit.
Keywords :
Inductance; Inductors; Mutual coupling; Power semiconductor switches; Power supplies; Regulators; Shape; Surges; Switching circuits; Voltage;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/TIA.1976.349401
Filename :
4157860
Link To Document :
بازگشت