Abstract
Traditionally the magnetic field distribution throughout an electrical machine core is obtained by positioning miniature enamelled copper wire search coils on test laminations stacked in an experimental core. However their physical presence, when inserted in a core, changes the flux and field distribution, creates localised stress and also an air gap between two adjacent laminations. To overcome this drawback, sensors comprising a thin film structure have been deposited on the surface of several laminations by vacuum evaporation of metals. Differences between the results obtained using conventional and thin film search coils are within the limits of experimental errors
Keywords
laminations; loss measurement; losses; magnetic cores; magnetic field measurement; magnetic sensors; magnetic thin film devices; vacuum deposited coatings; electrical machine core; laminations; loss measurement; magnetic field distribution; magnetic flux measurement; metals; search coils; thin film sensors; vacuum evaporation; Coils; Copper; Lamination; Loss measurement; Magnetic cores; Magnetic field measurement; Magnetic flux; Magnetic losses; Thin film sensors; Wire;