DocumentCode
794566
Title
A Technique for Trolley Arc Reduction
Author
Kumar, Ravi ; McConnell, Robert L. ; Cooley, Wils L.
Author_Institution
Packard Electric Division, General Motors Corporation, P. O. Box 431. Warren, OH 44486.
Issue
1
fYear
1985
Firstpage
154
Lastpage
157
Abstract
Arcing which occurs at the trolley shoe is one of the leading causes of electrical accidents in the coal mining industry. Arcs occur if trolley contact is made or broken under load. Some of these incidents are caused by improper vehicle operation and others occur as a result of unstable tracking conditions. The arcing can be reduced by detecting the disconnect condition and snubbing the arc by responsive control circuitry. Once the disconnect has been completed, reconnection under load can be controlled with the same circuitry. A system of accomplishing this arc reduction is presented along with the results of a simulation used to test the effectiveness of the technique. Guidelines are suggested for incorporating arc-reducing control circuitry into mine track vehicles.
Keywords
Circuits; Control systems; Electrical accidents; Inductance; Industry Applications Society; Injuries; Mining industry; Senior members; Vehicles; Voltage;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/TIA.1985.349675
Filename
4157963