DocumentCode :
794923
Title :
Field Weakening in Buried Permanent Magnet AC Motor Drives
Author :
Sneyers, Brigette ; Novotny, Donald W. ; Lipo, Thomas A.
Author_Institution :
Dienst ETEC, Vrije Universiteit Brussel, Pleinlaan 2, B-1050 Brussels, Belgium.
Issue :
2
fYear :
1985
fDate :
3/1/1985 12:00:00 AM
Firstpage :
398
Lastpage :
407
Abstract :
The usual uncoupled d - q model of salient pole synchronous machines (Park´s model) may be insufficient for accurate modeling of buried magnet permanent magnet machines. The addition of a nonbilateral coupling between the direct and quadrature axis equivalent circuits is shown to improve the steady-state model greatly. The cross coupling reactance has important implications in improving operation in the constant horsepower mode. In particular, it is demonstrated that the cross coupling term acts to reduce the effective internal voltage so that some field weakening can be achieved. The results should be useful in permanent magnet machine design for variable speed drive applications.
Keywords :
AC motors; Coupling circuits; Equivalent circuits; Permanent magnet machines; Permanent magnet motors; Reactive power; Servomotors; Synchronous machines; Synchronous motors; Voltage;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/TIA.1985.349661
Filename :
4157998
Link To Document :
بازگشت