• DocumentCode
    797059
  • Title

    Sampling effect in continuous-time small-signal modelling of average-current mode control

  • Author

    Jung, Y.-S. ; Youn, M.J.

  • Author_Institution
    Power Train Team, Hyundai Autonet Co. Ltd, Kyoungki-Do, South Korea
  • Volume
    149
  • Issue
    4
  • fYear
    2002
  • fDate
    7/1/2002 12:00:00 AM
  • Firstpage
    311
  • Lastpage
    316
  • Abstract
    Small-signal modelling of an average-current mode control is proposed. To analyse the characteristics of the control scheme, a continuous-time small-signal model is derived. The derivation comes mainly from the analysis of the sampling effect present in the current control loop. By using the mathematical interpretation of a practical sampler representing the sampling effect of a current control loop, the small-signal model of an average-current mode control can be derived. To show the usefulness of the proposed model both simulation and experiment are carried out. The results show that the predicted results by the proposed model are in much better agreement with the measured ones than those of the conventional model, even though a high gain of the compensation network of the current control loop is employed
  • Keywords
    compensation; electric current control; power supplies to apparatus; average-current mode control; compensation network; continuous-time small-signal modelling; current control loop; high gain; power supplies; sampler; sampling effect; small-signal model;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-2352
  • Type

    jour

  • DOI
    10.1049/ip-epa.20020362
  • Filename
    1022438