• DocumentCode
    797545
  • Title

    Preamplifier Noise Effects on Spectrometer Energy Resolution

  • Author

    Armantrout, G.A. ; Okubo, D.

  • Author_Institution
    Lawrence Radiation Laboratory, University of California Livermore, California 94550
  • Volume
    18
  • Issue
    1
  • fYear
    1971
  • Firstpage
    170
  • Lastpage
    174
  • Abstract
    Determining the detector contribution or the total system resolution of a Ge(Li) detector by quadrature subtraction or addition of electronic noise introduces serious error due to the non-Gaussian effects of carrier trapping. The contributions of electronic noise and detector spread to the total system resolution are found by computer spectrum simulation to be greater than expected. The conclusions are substantiated by agreement with experimental measurements.
  • Keywords
    Electron traps; Energy resolution; Gaussian noise; Noise shaping; Preamplifiers; Radiation detectors; Random variables; Shape; Spectroscopy; Statistical distributions;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1971.4325859
  • Filename
    4325859