DocumentCode
799717
Title
Monitoring of magnetic saturation level of a synchronous generator under load
Author
Matsuki, J. ; Okada, T. ; Yamanaka, M.
Author_Institution
Dept. of Electr. Eng., Kyoto Univ., Japan
Volume
10
Issue
2
fYear
1995
fDate
6/1/1995 12:00:00 AM
Firstpage
225
Lastpage
231
Abstract
This paper presents a new method to monitor magnetic saturation level of a synchronous generator operating in an electric power system. The proposed method makes use of air-gap permeance distributions, which can be derived from air-gap flux distributions measured by a search coil wound around a stator tooth of a generator. Tests were conducted on a laboratory-model power system to verify the validity of the proposed monitoring method. Test results under various operating conditions are presented to show a wide range of change in saturation level inside the generator. Its effects on generator performance in the power system and the benefits of the monitoring method are also discussed
Keywords
air gaps; machine testing; magnetic flux; magnetic variables measurement; monitoring; stators; synchronous generators; air-gap flux distributions; air-gap permeance distributions; condition monitoring; electric power system; generator performance; laboratory-model power system; magnetic saturation monitoring; search coil; stator tooth; synchronous generator; synchronous reactance; Air gaps; Coils; Magnetic flux; Monitoring; Saturation magnetization; Stators; Synchronous generators; System testing; Teeth; Wounds;
fLanguage
English
Journal_Title
Energy Conversion, IEEE Transactions on
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/60.391886
Filename