Abstract :
This paper presents a new method to monitor magnetic saturation level of a synchronous generator operating in an electric power system. The proposed method makes use of air-gap permeance distributions, which can be derived from air-gap flux distributions measured by a search coil wound around a stator tooth of a generator. Tests were conducted on a laboratory-model power system to verify the validity of the proposed monitoring method. Test results under various operating conditions are presented to show a wide range of change in saturation level inside the generator. Its effects on generator performance in the power system and the benefits of the monitoring method are also discussed
Keywords :
air gaps; machine testing; magnetic flux; magnetic variables measurement; monitoring; stators; synchronous generators; air-gap flux distributions; air-gap permeance distributions; condition monitoring; electric power system; generator performance; laboratory-model power system; magnetic saturation monitoring; search coil; stator tooth; synchronous generator; synchronous reactance; Air gaps; Coils; Magnetic flux; Monitoring; Saturation magnetization; Stators; Synchronous generators; System testing; Teeth; Wounds;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/60.391886
Filename :
391886
Link To Document :
بازگشت