Title :
Start up performance of load-commutated inverter fed synchronous machine drives
Author :
Sudhoff, S.D. ; Zivi, E.L. ; Collins, T.D.
Author_Institution :
Dept. of Electr. Eng., Missouri Univ., Rolla, MO, USA
fDate :
6/1/1995 12:00:00 AM
Abstract :
Load-commutated inverter (LCI) synchronous machine drives are common in the high power range. However, the starting performance of these systems is a concern since load-commutation cannot occur at arbitrarily low speeds. This paper compares three different starting strategies including one apparently neglected method-normal load commutation. In particular, it is shown that, depending on system parameters, it may be possible to start the system with no special provision for start up. A method to determine whether a given system can be started using load commutation is presented
Keywords :
commutation; invertors; load (electric); machine testing; machine theory; starting; synchronous motor drives; load-commutated inverter; normal load commutation; start-up performance; starting strategies; synchronous machine drives; system parameters; Circuits; Commutation; Genetic mutations; Inverters; Marine vehicles; Power systems; Rotors; Stators; Synchronous machines; Synchronous motors;
Journal_Title :
Energy Conversion, IEEE Transactions on