• DocumentCode
    800240
  • Title

    General Description and Performance Measurements on Desy Linac II Electron-Positron Injector

  • Author

    Pering, N.C. ; Roome, W.A. ; Rush, P.C. ; Seely, B.C.J. ; Febel, A. ; Schneemann, H. ; Stange, G.

  • Author_Institution
    Varian Associates, 611 Hansen Way, Palo Alto, California
  • Volume
    18
  • Issue
    3
  • fYear
    1971
  • fDate
    6/1/1971 12:00:00 AM
  • Firstpage
    579
  • Lastpage
    583
  • Abstract
    Measurements made during acceptance testing of the Desy electron-positron linear accelerator Indicate performance approaching the design value. The purpose of the linac is high-current Injection to the 7 GeV synchrotron and future electron-positron Injection into a 3 GeV storage ring now under construction. The linac consists of 12 5.2 meter constant-gradient sections driven by SLAC-type (TV) klystrons operating at 24 MW. Electron pulsed currents of 135 mA at 514 MeV In a 1% energy bin were measured during 24-hour tests. A positron current of 1.4 mA within an energy spread(¿E/E) of 1% bin and an emittance of 1¿ mRad.cm at 385 MeV has been measured. Electron load line and emittance data have been taken. Beampulse shortening of the SLAC-type occurs above 250 mA.
  • Keywords
    Current measurement; Energy measurement; Klystrons; Linear accelerators; Linear particle accelerator; Pulse measurements; Storage rings; Synchrotrons; TV; Testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1971.4326120
  • Filename
    4326120