General Description and Performance Measurements on Desy Linac II Electron-Positron Injector
Author :
Pering, N.C. ; Roome, W.A. ; Rush, P.C. ; Seely, B.C.J. ; Febel, A. ; Schneemann, H. ; Stange, G.
Author_Institution :
Varian Associates, 611 Hansen Way, Palo Alto, California
Volume :
18
Issue :
3
fYear :
1971
fDate :
6/1/1971 12:00:00 AM
Firstpage :
579
Lastpage :
583
Abstract :
Measurements made during acceptance testing of the Desy electron-positron linear accelerator Indicate performance approaching the design value. The purpose of the linac is high-current Injection to the 7 GeV synchrotron and future electron-positron Injection into a 3 GeV storage ring now under construction. The linac consists of 12 5.2 meter constant-gradient sections driven by SLAC-type (TV) klystrons operating at 24 MW. Electron pulsed currents of 135 mA at 514 MeV In a 1% energy bin were measured during 24-hour tests. A positron current of 1.4 mA within an energy spread(¿E/E) of 1% bin and an emittance of 1¿ mRad.cm at 385 MeV has been measured. Electron load line and emittance data have been taken. Beampulse shortening of the SLAC-type occurs above 250 mA.
Keywords :
Current measurement; Energy measurement; Klystrons; Linear accelerators; Linear particle accelerator; Pulse measurements; Storage rings; Synchrotrons; TV; Testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1971.4326120