• DocumentCode
    800300
  • Title

    Application of MR Element to Clamp-on Type Current Meter

  • Author

    Matsumoto, M. ; Haeiwa, T. ; Inoue, H. ; Tanaka, S.

  • Author_Institution
    Shinshu University.
  • Volume
    7
  • Issue
    5
  • fYear
    1992
  • fDate
    5/1/1992 12:00:00 AM
  • Firstpage
    413
  • Lastpage
    417
  • Abstract
    A new clamp-type ampmeter employing a magnetoresistive (MR) element has been constructed with a sub-milliampere order sensitivity and a wide frequency bandwidth. The sensor element is a 1000 to 1500 Ã… thick, 0.2 mm wide and 15 mm long evaporated thin film of 80/20 NiFe exhibiting a 2.5% magnetoresistive change. The MR element is mounted in the 0.2 mm gap of a ferrite core, which is wound with a 188-turn coil to provide a dc bias field (4 Oe) for linear sensitivity and to enable feedback detection. In the non-feedback mode, the system noise level (sensor and circuit) is 0.8 mV, equivalent to a 0.2 mA current. In feedback mode, this ammeter maintains linear sensitivity for currents of up to 0.4 A in the frequency range from dc to 10 kHz. The temperature stability was improved by compensating using element pairs.
  • Keywords
    Bandwidth; Feedback; Ferrites; Frequency; Magnetic cores; Magnetic sensors; Magnetoresistance; Thick film sensors; Thin film sensors; Wounds;
  • fLanguage
    English
  • Journal_Title
    Magnetics in Japan, IEEE Translation Journal on
  • Publisher
    ieee
  • ISSN
    0882-4959
  • Type

    jour

  • DOI
    10.1109/TJMJ.1992.4565407
  • Filename
    4565407