A Beam-Spill Monitor for LAMPF
Author :
Parker, J.R. ; Richardson, J.H. ; Oetting, J.D. ; Easley, J.D.
Author_Institution :
Los Alamos Scientific Laboratory University of California Los Alamos, New Mexico
Volume :
18
Issue :
3
fYear :
1971
fDate :
6/1/1971 12:00:00 AM
Firstpage :
825
Lastpage :
826
Abstract :
A beam-spill monitor system for the Los Alamos Meson Physics Facility (LAMPF) has been developed to meet the LAMPF requirements of fast action, reliability, long life in the LAMPF beam-channel radiation environment, and a variable sensitivity which can be changed by over 1000:1. Approximately fifty of these systems will be required, hence, low cost per system has been an important consideration in its development. The detector, an all-glass side window multiplier tube immersed in a mineral oil scintillator, has a useful range from 10-3 to 5 × 105 R/h. The electronics consist of a fast nonlinear electrometer, a threshold detector, a fast switch, a peak detector, and an envelope amplifier. The manner in which these interface with the LAMPF Fast Protect System and the analog and binary inputs to the control computer is described.
Keywords :
Control systems; Costs; Envelope detectors; Mesons; Minerals; Petroleum; Physics; Protection; Radiation monitoring; Switches;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee