DocumentCode :
801145
Title :
Clearing Radiation Darkened TV Lenses
Author :
Reigle, Donald L.
Author_Institution :
Argonne National Laboratory Argonne, Illinois
Volume :
18
Issue :
3
fYear :
1971
fDate :
6/1/1971 12:00:00 AM
Firstpage :
837
Lastpage :
838
Abstract :
The TV lenses used in high radiation areas here at the Zero Gradient Synchrotron (ZGS) become very brown and totally unusable within a short period of time. A method has been found whereby rotation of lenses from this area to exposure by UV light can keep a constant supply of usable lenses in service. Tests were also conducted on ZGS TV viewing ports to determine the clearing effect of UV on 3/4-in, 1-in, and 4-in-thick plate glass.
Keywords :
Assembly; Fluorescent lamps; Glass; Laboratories; Lenses; Synchrotron radiation; TV; Testing; Ultraviolet sources; Xenon;