DocumentCode
801950
Title
Determination of Commutation Sequence with a View to Eliminating Harmonics in Microprocessor-Controlled PWM Voltage Inverter
Author
Zuckerberger, A. ; Alexandrovitz, Abraham
Author_Institution
Department of Electrical Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel.
Issue
3
fYear
1986
Firstpage
262
Lastpage
270
Abstract
The commutation pattern of PWM inverters operated under elimination of harmonics and control of the fundamental wave amplitude is highly complex. The sequences determined by the proposed method permit control of the harmonic amplitudes of a single-phase and a three-phase inverter. A microcomputer (8085 CPU)¿controlled three-phase unit embodying this principle is described. It is designed for a three-phase output voltage in the 1-45 Hz interval with the 5th, 7th, and 11th harmonics eliminated, and with the fundamental wave amplitude proportional to the output frequency.
Keywords
Commutation; Fourier series; Frequency; Laboratories; Microcomputers; Microprocessors; Pulse width modulation inverters; Voltage control; Waves;
fLanguage
English
Journal_Title
Industrial Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0278-0046
Type
jour
DOI
10.1109/TIE.1986.350232