Quantitative 3-D diagnostic ultrasound imaging using a modified transducer array and an automated image tracking technique
Author
Hossack, John A. ; Sumanaweera, Thilaka S. ; Napel, Sandy ; Ha, Jun S.
Author_Institution
Dept. of Biomed. Eng., Virginia Univ., Charlottesville, VA, USA
Volume
49
Issue
8
fYear
2002
Firstpage
1029
Lastpage
1038
Abstract
An approach for acquiring dimensionally accurate three-dimensional (3-D) ultrasound data from multiple 2-D image planes is presented. This is based on the use of a modified linear-phased array comprising a central imaging array that acquires multiple, essentially parallel, 2-D slices as the transducer is translated over the tissue of interest. Small, perpendicularly oriented, tracking arrays are integrally mounted on each end of the imaging transducer. As the transducer is translated in an elevational direction with respect to the central imaging array, the images obtained by the tracking arrays remain largely coplanar. The motion between successive tracking images is determined using a minimum sum of absolute difference (MSAD) image matching technique with subpixel matching resolution. An initial phantom scanning-based test of a prototype 8 MHz array indicates that linear dimensional accuracy of 4.6% (2 /spl sigma/) is achievable. This result compares favorably with those obtained using an assumed average velocity [31.5% (2 /spl sigma/) accuracy] and using an approach based on measuring image-to-image decorrelation [8.4% (2 /spl sigma/) accuracy]. The prototype array and imaging system were also tested in a clinical environment, and early results suggest that the approach has the potential to enable a low cost, rapid, screening method for detecting carotid artery stenosis. The average time for performing a screening test for carotid stenosis was reduced from an average of 45 minutes using 2-D duplex Doppler to 12 minutes using the new 3-D scanning approach.
Keywords
biomedical transducers; biomedical ultrasonics; blood flow measurement; image matching; motion estimation; ultrasonic transducer arrays; 12 min; 8 MHz; automated image tracking technique; carotid artery stenosis detection; central imaging array; clinical environment; coplanar images; dimensionally accurate three-dimensional ultrasound data; image motion estimation; linear dimensional accuracy; linear-phased array; minimum sum of absolute difference image matching technique; modified transducer array; multiple 2-D image planes; multiple parallel 2-D slices; perpendicularly oriented tracking arrays; phantom scanning-based test; quantitative 3-D diagnostic ultrasound imaging; rapid screening method; subpixel matching resolution; tissue; Image matching; Image resolution; Imaging phantoms; Prototypes; Testing; Tracking; Ultrasonic imaging; Ultrasonic transducer arrays; Ultrasonic transducers; Velocity measurement; Carotid Arteries; Carotid Stenosis; Humans; Image Processing, Computer-Assisted; Imaging, Three-Dimensional; Transducers; Ultrasonography;
fLanguage
English
Journal_Title
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher
ieee
ISSN
0885-3010
Type
jour
DOI
10.1109/TUFFC.2002.1026015
Filename
1026015
Link To Document