DocumentCode
805751
Title
Pulsed Heavy Ion Source for the Bevatron
Author
Grunder, H.A. ; Richter, R.M. ; Tekawa, M.M. ; Zajec, E.
Author_Institution
Lawrence Berkeley Laboratory University of California Berkeley, California
Volume
19
Issue
2
fYear
1972
fDate
4/1/1972 12:00:00 AM
Firstpage
208
Lastpage
211
Abstract
A Phillips ion gauge source (Fig. 1) of the type used by the heavy ion accelerator in Berkeley has been adapted for use at the Bevatron. The objective was to achieve high charge state ions (4+, 5+) of carbon and nitrogen. All source parameters are pulsed. The ion source performance regarding linac acceleration is discussed. The light ion (deuteron, alpha) performance of the PIG source and duoplasmatron is compared.
Keywords
Acceleration; Cathodes; Insulation; Ion sources; Lenses; Linear particle accelerator; Magnetic devices; Nitrogen; Testing; Titanium;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1972.4326657
Filename
4326657
Link To Document