DocumentCode
806605
Title
Groove Detectors from High-Purity Germanium
Author
Baertsch, R.D.
Author_Institution
General Electric Corporate Research and Development Schenectady, New York 12301
Volume
19
Issue
3
fYear
1972
fDate
6/1/1972 12:00:00 AM
Firstpage
275
Lastpage
280
Abstract
Detector have been fabricated from pure germanium with a lithium diffused N+ contact, and a P+ contact which is ion implanted in a dc glow discharge in boron trifluoride. A deep groove is used to increase the breakdown voltage. Measurements of the current-voltage characteristics of these detectors after temperature cycling are reported. The correlation of smooth etch pits with severe trapping in pure germanium detectors is shown. Finally, the performance of a few large detectors is given.
Keywords
Boron; Breakdown voltage; Current measurement; Current-voltage characteristics; Detectors; Germanium; Glow discharges; Lithium; Temperature; Voltage measurement;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1972.4326738
Filename
4326738
Link To Document