• DocumentCode
    806605
  • Title

    Groove Detectors from High-Purity Germanium

  • Author

    Baertsch, R.D.

  • Author_Institution
    General Electric Corporate Research and Development Schenectady, New York 12301
  • Volume
    19
  • Issue
    3
  • fYear
    1972
  • fDate
    6/1/1972 12:00:00 AM
  • Firstpage
    275
  • Lastpage
    280
  • Abstract
    Detector have been fabricated from pure germanium with a lithium diffused N+ contact, and a P+ contact which is ion implanted in a dc glow discharge in boron trifluoride. A deep groove is used to increase the breakdown voltage. Measurements of the current-voltage characteristics of these detectors after temperature cycling are reported. The correlation of smooth etch pits with severe trapping in pure germanium detectors is shown. Finally, the performance of a few large detectors is given.
  • Keywords
    Boron; Breakdown voltage; Current measurement; Current-voltage characteristics; Detectors; Germanium; Glow discharges; Lithium; Temperature; Voltage measurement;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1972.4326738
  • Filename