• DocumentCode
    806882
  • Title

    The Radiation Area Monitoring System at NAL

  • Author

    Shafer, R.

  • Author_Institution
    National Accelerator Laboratory Batavia, Illinois 60510
  • Volume
    19
  • Issue
    3
  • fYear
    1972
  • fDate
    6/1/1972 12:00:00 AM
  • Firstpage
    457
  • Lastpage
    459
  • Abstract
    A digital multiplexing system for monitoring radiation levels adjacent to approximately eight (8) miles of beam line with over 500 detectors is being implemented at NAL. Data from individual detectors is collected in a central area via a dedicated-time-slot digital multiplexing system, designed for high reliability rather than high bit rates, and is completely independent of any accelerator control system. Data processing is performed in a hardwired core memory system, and record keeping is accomplished via a link to the Accelerator Control Computer. A wide variety of oscilloscope displays are available for selective intensification of data.
  • Keywords
    Centralized control; Clocks; Computerized monitoring; Control systems; Data processing; Particle beams; Personnel; Radiation detectors; Radiation monitoring; Transmitters;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1972.4326765
  • Filename