DocumentCode
808751
Title
The PeakSum system for the EPSI experiment
Author
Galeotti, S. ; Morsani, F. ; Passuello, D. ; Rossi, F.
Author_Institution
INFN, Pisa, Italy
Volume
39
Issue
5
fYear
1992
fDate
10/1/1992 12:00:00 AM
Firstpage
1307
Lastpage
1310
Abstract
The EPSI experiment trigger system needs to know how many γ photons are generated by the K0 decay, what their total energy is, whether their Barycentre is on the beam axis, and where is the decay vertex position along the beam axis is: this parameter is related to the second-order momentum value. The PeakSum system was conceived to calculate all these quantities with a convenient precision based on custom VLSI chips. It is a pipelined circuit, designed to work with a pipeline clock period of 25 ns, but its components can be easily redesigned to have no internal pipeline stages. The heart of the system is the PeakSum chip, which is described
Keywords
CP invariance; VLSI; electromagnetic decays; gamma-ray detection and measurement; kaon decay; nuclear electronics; Barycentre; EPSI experiment trigger system; K0 decay; PeakSum chip; PeakSum system; beam axis; custom VLSI chips; decay vertex position; gamma photons; kaon decay; pipeline clock period; pipelined circuit; second-order momentum value; Adders; Clocks; Counting circuits; Filters; Pipeline processing; Process design; Signal generators; Table lookup; Time measurement; Very large scale integration;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.173196
Filename
173196
Link To Document