• DocumentCode
    808916
  • Title

    Versatile, Modular Readout System for CAMAC Scalers

  • Author

    Horelick, Dale

  • Author_Institution
    Stanford Linear Accelerator Center Stanford University, Stanford, California 94305
  • Volume
    20
  • Issue
    1
  • fYear
    1973
  • Firstpage
    574
  • Lastpage
    580
  • Abstract
    A display and readout system for CAMAC scalers will be described which has been in use at SLAC for over a year. Flexibility and versatility are the keynotes of the system, which includes a modular quad display unit employing highly readable Nixie tubes. Other units which may be connected to the expandable bus include an X-Y scope display and a preset count module. The system employs a simple, but versatile CAMAC crate controller. Capability for connection to computers is included, and the system has been interfaced to several different computers.
  • Keywords
    CAMAC; Communication cables; Computer displays; Computer interfaces; Control systems; Guidelines; Humans; Impedance; Information retrieval; Linear accelerators;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1973.4326966
  • Filename
    4326966