• DocumentCode
    810638
  • Title

    Effects of external pressure on arteries distal to the cuff during sphygmomanometry

  • Author

    Nitzan, Meir ; Rosenfeld, Chaim ; Weiss, A. Teddy ; Grossman, Ehud ; Patron, Amikam ; Murray, Alan

  • Author_Institution
    Ninbar Ltd., Jerusalem, Israel
  • Volume
    52
  • Issue
    6
  • fYear
    2005
  • fDate
    6/1/2005 12:00:00 AM
  • Firstpage
    1120
  • Lastpage
    1127
  • Abstract
    The aim of this study was to examine the effect on distal arteries of external pressure, applied by upper arm sphygmomanometer cuff. Photoplethysmographic (PPG) signals were measured on the index fingers of 44 healthy male subjects, during the slow decrease of cuff air pressure. For each pulse the ratio of PPG amplitude to its baseline (AM/BL) and its time delay (ΔTD) relative to the contralateral hand were determined as a function of cuff pressure. At cuff pressures equal to systolic blood pressure, pulses reappeared with the pulse time delay in the cuffed arm significantly greater than in the noncuffed arm, with (ΔTD)(mean±SD)150±31 ms (p<0.001). At cuff pressures equal to diastolic blood pressure (81±12 mmHg),ΔTD was 42±19 ms (p<0.001), and at 50 mmHg, which is below diastolic blood pressure, (ΔTD) was still significantly positive at 6±9 ms (p<0.001). AM/BL relative to its initial value rose at cuff pressures between systolic and diastolic blood pressure, then deceased to 0.6±0.41 (p<0.001) at diastolic blood pressure and 0.54±0.24 (p<0.001) at 50 mmHg. The changes in (ΔTD) and AM/BL can be interpreted as originating from changes in the compliance of conduit arteries and small arteries with cuff inflation and deflation.
  • Keywords
    blood pressure measurement; blood vessels; delays; plethysmography; conduit arteries; cuff deflation; cuff inflation; diastolic blood pressure; distal arteries; external pressure effects; photoplethysmographic signals; pulse time delay; small arteries; systolic blood pressure; upper arm sphygmomanometer cuff; Arterial blood pressure; Arteries; Blood pressure; Delay effects; Electrocardiography; Fingers; Physics; Pressure measurement; Pulse measurements; Ultrasonic variables measurement; Arterial blood pressure; arterial compliance; photoplethysmography; pulse wave velocity; Adolescent; Adult; Aged; Blood Pressure; Blood Pressure Determination; Fingers; Humans; Male; Middle Aged; Physical Stimulation; Reproducibility of Results; Sensitivity and Specificity; Sphygmomanometers; Vascular Resistance;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2005.846710
  • Filename
    1431085