DocumentCode
810693
Title
Performance of Transductors for Precision High-Current Measurement and Control
Author
Fuja, R.E. ; Praeg, W.F.
Author_Institution
Argonne National Laboratory Argonne, Illinois
Volume
20
Issue
3
fYear
1973
fDate
6/1/1973 12:00:00 AM
Firstpage
411
Lastpage
413
Abstract
In order to find transductors suitable for the requirements of the ZGS, four commercial transductors were compared with a precision coaxial shunt. The results of these measurements, which determine the stability, linearity, hysteresis, frequency response, output ripple, coefficients of temperature and line voltage, and effects of magnetic stray fields, are reported.
Keywords
Coaxial components; Linearity; Magnetic field measurement; Monitoring; Power supplies; Stability; Temperature control; Temperature sensors; Testing; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1973.4327136
Filename
4327136
Link To Document