• DocumentCode
    811046
  • Title

    Computer Programs for AGS Injection

  • Author

    Brown, H.N. ; Claus, J.

  • Author_Institution
    Brookhaven National Laboratory Upton, New York
  • Volume
    20
  • Issue
    3
  • fYear
    1973
  • fDate
    6/1/1973 12:00:00 AM
  • Firstpage
    528
  • Lastpage
    530
  • Abstract
    Since the injection system of the AGS requires very tight control over many parameters, computer programs were written to achieve this. One program initiates an emittance measurement device and reduces its output data to provide the characteristics of the linac beam. The second program utilizes these results to set six quadrupoles and four bending magnets so that requested beam parameters are obtained at the inflector exit. A third program measures the circulating beam and attempts to maximize it by adjustment of quadrupoles and bending magnets. These programs and our experience in using them on-line are described.
  • Keywords
    Algorithms; Automatic control; Control systems; Density measurement; Laboratories; Linear particle accelerator; Magnets; Particle beams; Protons; Synchrotrons;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1973.4327168
  • Filename
    4327168