DocumentCode
811046
Title
Computer Programs for AGS Injection
Author
Brown, H.N. ; Claus, J.
Author_Institution
Brookhaven National Laboratory Upton, New York
Volume
20
Issue
3
fYear
1973
fDate
6/1/1973 12:00:00 AM
Firstpage
528
Lastpage
530
Abstract
Since the injection system of the AGS requires very tight control over many parameters, computer programs were written to achieve this. One program initiates an emittance measurement device and reduces its output data to provide the characteristics of the linac beam. The second program utilizes these results to set six quadrupoles and four bending magnets so that requested beam parameters are obtained at the inflector exit. A third program measures the circulating beam and attempts to maximize it by adjustment of quadrupoles and bending magnets. These programs and our experience in using them on-line are described.