Title :
Development of a Totally Enclosed Fan-Cooled Traction Motor
Author :
Mizuno, Seiya ; Noda, Satoshi ; Matsushita, M. ; Koyama, Tomofumi ; Shiraishi, Shinichi
Author_Institution :
Fuchu Complex, Toshiba Corp., Fuchu, Japan
Abstract :
The intake of dust and dirt contained outside the air into the motor while driving causes the maintenance of dismantling and clean-up operation once every three years. Moreover, excessive acoustic noise during high-speed operation is produced by the cooling fan on the rotor. Totally enclosed airtight motor was developed not only to deal with the dust-intake problem but also to reduce acoustic noise. This motor eliminates the requirement of periodical dismantling and clean-up operation. Excessive noise of internal cooling fan was decreased by newly developed uneven pitch blade fan. Further, traction motor without external fan was developed by thermofluid simulation. Acoustic noise and temperature rise of these motor were measured and compared.
Keywords :
fans; traction motors; clean-up operation maintenance; cooling fan; dismantling maintenance; dust-intake problem; excessive acoustic noise reduction; high-speed operation; internal cooling fan; pitch blade fan; thermofluid simulation; totally enclosed airtight motor; totally enclosed fan-cooled traction motor; Acoustic noise uneven pitch fan; induction motor; totally enclosed fan-cooled traction motor;
Journal_Title :
Industry Applications, IEEE Transactions on
DOI :
10.1109/TIA.2013.2256872