DocumentCode
813887
Title
High Resolution Cryogenic Spark Chambers
Author
Atac, M. ; Taylor, W.E.
Author_Institution
National Accelerator Laboratory Batavia, Illinois
Volume
21
Issue
1
fYear
1974
Firstpage
65
Lastpage
69
Abstract
A cluster of four narrow gap (2.5 mm) spark chambers containing 8 wires per millimeter has been built and operated at low temperatures (as low as 118°K). Results obtained from these chambers indicate that the width of the spark column is reduced at lower temperatures due to the increased gas density. Electron diffusion and deviation of the spark column from the true particle trajectory are greatly reduced at lower temperatures with narrow gap spark chambers. Space resolutions less than ¿ = 70 microns (HWHM) has been achieved and even better resolutions are predicted from the observed temperature dependence.
Keywords
Copper; Cryogenics; Electrons; Energy resolution; Nitrogen; Particle tracking; Pulse amplifiers; Sparks; Temperature sensors; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1974.4327445
Filename
4327445
Link To Document