DocumentCode
813926
Title
The Needle Chamber : A New Type of X-Y Detector Using the Properties of Gaseous Multiplication
Author
Grunberg, C. ; Le Devéhat, J.
Author_Institution
Département de Physique Nucléaire CEN-Saclay, B.P. 2, 91190 Gif-sur-Yvette, France
Volume
21
Issue
1
fYear
1974
Firstpage
89
Lastpage
92
Abstract
A new type of detector, based on gaseous multiplication is presented here under. It is made of needle arrays, each needle behaving as an independent proportional counter. Thus, it has advantages of multiwire-proportional chambers and many others, mainly high-counting rate per surface unit, high mechanical reliability. All these features make this counter of large interest in a lot of fields of works.
Keywords
Anodes; Cathodes; Counting circuits; Detectors; Electrodes; Filling; Needles; Particle tracking; Periodic structures; Wire;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1974.4327449
Filename
4327449
Link To Document