DocumentCode
814970
Title
Experience with a Digital Noise Analysis System in Subcriticality Measurements on a Mockup of the FFTF
Author
Paré, V.K. ; Kryter, R.C. ; Mihalczo, J.T.
Author_Institution
Oak Ridge National Laboratory Oak Ridge, Tennessee 37830
Volume
21
Issue
1
fYear
1974
Firstpage
767
Lastpage
770
Abstract
A digital Fourier analyzer was programmed to perform reactor neutron noise analysis measurements and on-line processing of the data to obtain the steady-state reactivity. The system is suitable for recovering cross spectral density with low correlated-signal component and for repetitive measurements with efficient use of reactor time.
Keywords
Detectors; Digital systems; Hardware; Inductors; Laboratories; Manufacturing; Neutrons; Noise measurement; Performance analysis; Surveillance;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1974.4327547
Filename
4327547
Link To Document