DocumentCode
815142
Title
The HE 1 MWPC Acquisition System
Author
Auriol, E ; Cohen, L. ; Dupont, J. ; Grunberg, C. ; Leconte, Ph. ; Le Devehat, J. ; Lefebvre, M. ; Lemarchand, C. ; Millaud, J. ; Mougey, J. ; Ho, Phan Xuan ; Priou, M. ; Royer, D. ; Sick, I.
Author_Institution
Département de Physique Nucléaire, CEN-Saclay, BP 2 91190 Gif-sur-Yvette, France
Volume
21
Issue
1
fYear
1974
Firstpage
862
Lastpage
866
Abstract
This system has been designed to fullfill the needs of (e,e´) and (e,e´p) experiments at the 600 MeV Linear Accelerator of Saclay. The configuration of the experimental set-up consists in two high resolution spectrometers and associated detectors. Localization of the particle is done for each spectrometer, through a set of two multiwires proportional chambers; one being in the focal surface of the spectrometer. The time definition of the event will be taken from the fast coincidence of two high speed detector arrays. The main characteristic of this system is that it must accommodate the necessary high counting rate. The essential features of this realization are briefly described hereunder.
Keywords
Background noise; Computer interfaces; Detectors; Helium; Logic; Optical noise; Photomultipliers; Pulse amplifiers; Read only memory; Registers;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1974.4327562
Filename
4327562