DocumentCode :
816347
Title :
Overcurrent Detector for Wire Chamber High Voltage Supplies
Author :
Kerns, Cordon R.
Author_Institution :
Fermi National Accelerator Laboratory Batavia, Illinois 60510
Volume :
22
Issue :
1
fYear :
1975
Firstpage :
441
Lastpage :
445
Abstract :
A high-potential isolated circuit for remotely measuring, monitoring, and crowbarring high-voltage power supplies at a variable preset current threshold level is described. It is presently being used in a high-energy physics experiment utilizing proportional chambers which require self-destruct protection from high-current discharges. An absolute current threshold of one microampere has been achieved. The circuit is not damaged by momentary current overloads of ten amperes or less.
Keywords :
Circuits; Current measurement; Detectors; Physics; Power measurement; Power supplies; Protection; Remote monitoring; Voltage; Wire;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1975.4327677
Filename :
4327677
Link To Document :
بازگشت