    816847
  • Title

    Central Tritium Monitor for Candu Nuclear Power Stations

  • Author

    Osborne, R.V.

  • Author_Institution
    Atomic Energy of Canada Limited, Chalk River Nuclear Laboratories Chalk River, Ontario KOJ IJO, Canada
  • Volume
    22
  • Issue
    1
  • fYear
    1975
  • Firstpage
    676
  • Lastpage
    680
  • Abstract
    Tritiated water vapour in a sample air stream is collected in a water stream and measured in a scintillation flow counter. One ¿Ci/m3 can be detected with a response time constant of several minutes. The instrument, engineered for unattended operation, is insensitive to other airborne radionuclides, gamma radiation, and humidity variation.
  • Keywords
    Delay; Fluid flow measurement; Gamma rays; Humidity; Instruments; Monitoring; Power engineering and energy; Power generation; Radiation detectors; Solid scintillation detectors;