DocumentCode
816847
Title
Central Tritium Monitor for Candu Nuclear Power Stations
Author
Osborne, R.V.
Author_Institution
Atomic Energy of Canada Limited, Chalk River Nuclear Laboratories Chalk River, Ontario KOJ IJO, Canada
Volume
22
Issue
1
fYear
1975
Firstpage
676
Lastpage
680
Abstract
Tritiated water vapour in a sample air stream is collected in a water stream and measured in a scintillation flow counter. One ¿Ci/m3 can be detected with a response time constant of several minutes. The instrument, engineered for unattended operation, is insensitive to other airborne radionuclides, gamma radiation, and humidity variation.
Keywords
Delay; Fluid flow measurement; Gamma rays; Humidity; Instruments; Monitoring; Power engineering and energy; Power generation; Radiation detectors; Solid scintillation detectors;