DocumentCode :
816894
Title :
Design Parameters and Test Results for a Fission Counter Intended for Operation up to 750°F at High Gamma Dose Rates
Author :
Pare, V.K. ; Clay, W.T. ; De Lorenzo, J.T. ; Guerrant, G.C.
Author_Institution :
Oak Ridge National Laboratory Oak Ridge, Tennessee 37830
Volume :
22
Issue :
1
fYear :
1975
Firstpage :
696
Lastpage :
701
Abstract :
A fission counter was built and successfully tested for operation at 750°F and gamma dose rates up to 6 × 106 R/hr. Results from gamma and neutron tests were compared with theoretical predictions and used to optimize the performance of the counters.
Keywords :
Cables; Coatings; Counting circuits; Electrodes; Electromagnetic interference; Inductors; Monitoring; Neutrons; Radiation detectors; Testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1975.4327731
Filename :
4327731
Link To Document :
بازگشت