• DocumentCode
    816953
  • Title

    Automated Nondestructive Assay Instrumentation for Nuclear Materials Safeguards

  • Author

    East, L.V. ; Martin, E.R. ; Atwell, T.L. ; Augustson, R.H. ; Menlove, H.O.

  • Author_Institution
    Nuclear Analysis Research Group University of California Los Alamos Scientific Laboratory Los Alamos, New Mexico 87544
  • Volume
    22
  • Issue
    1
  • fYear
    1975
  • Firstpage
    739
  • Lastpage
    743
  • Abstract
    Four systems developed at the Los Alamos Scientific Laboratory for nondestructive analysis of nuclear fuel materials will be described. These systems utilize either minicomputers or a programmable calculator for measurement control and data analysis, and are typical of a variety of automated measurement systems developed for nuclear materials safeguards applications.
  • Keywords
    Attenuation; Automatic control; Data analysis; Gamma ray detection; Gamma ray detectors; Gamma rays; Instruments; Laboratories; Neutrons; Nuclear measurements;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1975.4327738
  • Filename
    4327738