• DocumentCode
    817436
  • Title

    Design features of the Bad Creek pumped storage project generators motors

  • Author

    McLaren, D.G. ; Herrin, R.C. ; Wright, R.H.

  • Author_Institution
    GE Canada Inc., Peterborough, Ont., Canada
  • Volume
    4
  • Issue
    2
  • fYear
    1989
  • fDate
    6/1/1989 12:00:00 AM
  • Firstpage
    191
  • Lastpage
    196
  • Abstract
    The four pumped-storage generator/motors for the Bad Creek project in Oconee County, SC, are distributed. Consideration is given to the general unit construction, the cooling system, the thrust bearing, and the structural design. The most unique design aspect of these units is the arrangement of the forced fan ventilation system, which uses twenty motor-driven fans to direct air in very controlled paths. The adequacy of the system was verified by prototype laboratory testing. Field testing is planned to verify the system and machine efficiencies at the time of unit startup.<>
  • Keywords
    electric generators; electric motors; project engineering; pumped-storage power stations; Bad Creek pumped storage project; USA; construction; design; generator/motors; project engineering; testing; ventilation system; Control systems; Hydraulic turbines; Induction generators; Induction motors; Lighting control; Power generation; Power supplies; Reservoirs; Rotors; Shafts;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/60.17911
  • Filename
    17911