DocumentCode :
817774
Title :
Radiation Hardened Proton Meter for Fermilab External Beam Lines
Author :
Kerns, Cordon R.
Author_Institution :
Fermi National Accelerator Laboratory Batavia, Illinois 60510
Volume :
22
Issue :
3
fYear :
1975
fDate :
6/1/1975 12:00:00 AM
Firstpage :
1104
Lastpage :
1108
Abstract :
A beam line current and charge monitor has been in use for several months with the following characteristics: (1) beam toroid in high radiation area 200 feet from electronics, and within 30 feet of the 140, 000 ampere pulsed neutrino horn, (2) response time adequate to permit accurate (1%) measurement of 1 turn fast-extracted beam, (3) digital and analogue readouts for full scale ranges of 2 × 1012, 1 × 1013, and 5 × 1013 protons per pulse, (4) computer readout and standardization via CAMAC, (5) pulse-to-pulse repeatability is 1 in 1000 on test pulses. There is no interference from the horn, which pulses at the same time as the beam.
Keywords :
Area measurement; Delay; Electronic equipment testing; Neutrino sources; Particle beam measurements; Particle beams; Protons; Pulse measurements; Radiation hardening; Radiation monitoring;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1975.4327821
Filename :
4327821
Link To Document :
بازگشت